Rayleigh3105
Copy link

No description provided.

@Sn0w3y
Copy link
Contributor

Sn0w3y commented Apr 9, 2024

@Rayleigh3105 this is 100% not finished, maybe consider marking this PR as draft as I and the others know based on the "Copy-Paste" it is not finished yet - will add some comments beforehand :)

See for e.g.:

https://openems.github.io/openems.io/openems/latest/contribute/coding-guidelines.html

Your complete Checkstyle is missing, there are no tests, and so on and so forth

Copy link
Contributor

@Sn0w3y Sn0w3y left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

To maintain transparency, I believe it would be more efficient for @sfeilmeier if you could address the issues in this pull request before resubmitting it. Like you, I am diligently working on my pull requests and acknowledge that I am not without fault. Based on my observations, @sfeilmeier is undoubtedly busy and appreciates contributions. However, he also faces the challenge of reviewing a significant amount of code that may be redundant, unnecessary, or incorrect in some pull requests, including some of my own.

@AttributeDefinition(name = "Modbus-Unit-ID", description = "Unit ID of Modbus bridge.")
int unit_id() default 0;

@AttributeDefinition(name = "Power limit on PowerDecreaseCausedByOvertemperature error; '0' to disable power limit logic", description = "")
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

What does this Config Point do?

Maybe consider changing it to something like:

@AttributeDefinition(name = "ThermalPowerLimitControl", description = "Defines the power limit adjustment in response to overtemperature events. Set to '0' to disable.")

Copy link
Author

@Rayleigh3105 Rayleigh3105 Apr 15, 2024

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Done - Removed.

@AttributeDefinition(name = "Surplus Feed-In: PV-Limit on PowerDecreaseCausedByOvertemperature", description = "")
int surplusFeedInPvLimitOnPowerDecreaseCausedByOvertemperature() default 5_000;

String webconsole_configurationFactory_nameHint() default "Deye [{id}]";
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Deye what? Maybe also consider to refactor the Config if all of the Settings are needed for this "quite Simple" ESS ? As this all is copied from Fenecon Commercial 40 personally I do not think it is needed to set all these things up here

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Done.

private static final int MIN_REACTIVE_POWER = -10000;

private static final int MAX_REACTIVE_POWER = 10000;

Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

why are these for e.g. Hard Coded ? Aren't there more then one Combinations Possible ?

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This is just copied from commerical 40. Dont know if I need these.

ModbusComponent.ChannelId.values(), //
SymmetricEss.ChannelId.values(), //
ManagedSymmetricEss.ChannelId.values(), //
HybridEss.ChannelId.values(), //
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Are all of these really needed ? Seems like most of them are Commercial specific...


private LocalDateTime lastDefineWorkState = null;

private void defineWorkState() {
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Is there a "Work State" on Deye ?

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Deye does have a run state.
Bildschirmfoto 2024-04-15 um 10 07 49

return new Constraint[] { //
this.createPowerConstraint("Commercial40 Min Reactive Power", Phase.ALL, Pwr.REACTIVE,
Relationship.GREATER_OR_EQUALS, MIN_REACTIVE_POWER), //
this.createPowerConstraint("Commercial40 Max Reactive Power", Phase.ALL, Pwr.REACTIVE,
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Commercial 40 ?

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Done.

public class SurplusFeedInHandler {

private static final int GOING_DEACTIVATED_MINUTES = 15;
private static final float PV_LIMIT_FACTOR = 0.9f;
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

All of these values are Commercial 40 related i guess..

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Removed.

var areSurplusConditionsMet = this.areSurplusConditionsMet(this.parent, chargers, config);

if (chargers.isEmpty()) {
// Is no Charger set (i.e. is this not a Commercial 40-40 "DC")
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Again commercial 40 related ?

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Removed.

@Sn0w3y
Copy link
Contributor

Sn0w3y commented Apr 10, 2024

@Rayleigh3105 you completely reverted my changes again..

I am sorry but as @sfeilmeier also told me please consider looking into the getting started and also learn some things about github before creating a PR please.. also use the getting started please !

@Sn0w3y
Copy link
Contributor

Sn0w3y commented Apr 10, 2024

@Rayleigh3105 reformatted it again, removed unused Classes again, please do not revert as it is not needed :)

@Rayleigh3105
Copy link
Author

@Sn0w3y Ahh sorry never wanted to create a PR this early. I just played around in gitHub. I´m trying to sort out the code in the next days 😆

@Rayleigh3105 Rayleigh3105 changed the title Production meter DRAFT - Production meter Apr 11, 2024
@Rayleigh3105 Rayleigh3105 changed the title DRAFT - Production meter DRAFT - Implementation DEYE SUN-12K-SG04LP3-EU Apr 11, 2024
@Rayleigh3105 Rayleigh3105 marked this pull request as draft April 11, 2024 08:29
Copy link

Code Coverage

Copy link

Code Coverage

Comment on lines 91 to 110
final Consumer<Value<Integer>> calculate = ignore -> {
final Integer generatorPower = meter.getActivePowerGen().getNextValue().get();
Integer generatorPowerToSet = 0;

if (generatorPower > 32768) {
generatorPowerToSet = generatorPower - 65536;
} else {
generatorPowerToSet = generatorPower;
}

meter._setActivePower(TypeUtils.sum(//
meter.getActivePowerS1Channel().getNextValue().get(), //
meter.getActivePowerS2Channel().getNextValue().get(), //
meter.getActivePowerS3Channel().getNextValue().get(), //
meter.getActivePowerS4Channel().getNextValue().get(), generatorPowerToSet)); //
};
meter.getActivePowerS1Channel().onSetNextValue(calculate);
meter.getActivePowerS2Channel().onSetNextValue(calculate);
meter.getActivePowerS3Channel().onSetNextValue(calculate);
meter.getActivePowerS4Channel().onSetNextValue(calculate);
meter.getActivePowerGen().onSetNextValue(calculate);
Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

@Sn0w3y Is this the right way to implement the Gen Port on a inverter?

Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

What do you mean with "Gen Port" ?

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Deye does have a port to plug in a Generator source. Like a Diesel generator. So the values what it generates are now written to active power.

Copy link
Author

@Rayleigh3105 Rayleigh3105 Apr 15, 2024

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I think the right behavior for this case would be to implement a new meter for the generator Port. It is a external source which can produce energy, but also take energy. Maybe it would be nice to view the values of the generator port in the UI
Bildschirmfoto 2024-04-15 um 09 26 19

https://www.akkudoktor.net/forum/deye-wechselrichter/deye-12k-frage-zum-generator-port-wechsel-der-nutzart/

@Rayleigh3105
Copy link
Author

Rayleigh3105 commented Apr 12, 2024

To maintain transparency, I believe it would be more efficient for @sfeilmeier if you could address the issues in this pull request before resubmitting it. Like you, I am diligently working on my pull requests and acknowledge that I am not without fault. Based on my observations, @sfeilmeier is undoubtedly busy and appreciates contributions. However, he also faces the challenge of reviewing a significant amount of code that may be redundant, unnecessary, or incorrect in some pull requests, including some of my own.

Yeah never meant to open the PR in this stage, did forgot to make it a draft. Thanks for your participation.

@Rayleigh3105 Rayleigh3105 reopened this Apr 15, 2024
@Sn0w3y
Copy link
Contributor

Sn0w3y commented Apr 15, 2024

@Rayleigh3105 could you please check if the Code works for your Deye ?

Copy link

Code Coverage

@Rayleigh3105
Copy link
Author

@Sn0w3y Deplyoed it to the raspi. Code still working 👍 Now running on commit 3082fed

@Rayleigh3105 Rayleigh3105 force-pushed the production_meter branch 2 times, most recently from da67180 to e05dded Compare April 16, 2024 06:46
@Rayleigh3105
Copy link
Author

Rayleigh3105 commented Apr 16, 2024

@Sn0w3y Deplyoed it to the raspi. Code still working 👍 Now running on commit 3082fed

Hi @Sn0w3y, unfurtunally it did not work as expected. Thee ESS broke with this change of the code. I reseted the branch and tested every commit. Now its working again.
Bildschirmfoto 2024-04-16 um 08 41 53
Bildschirmfoto 2024-04-16 um 08 42 36